Opens in a new tab

Case study · Industrial

Shelters for Housing IT Equipment

We designed and manufactured a series of shelters to house IT equipment, with R30 intumescent paint applied.

Finished shelter for IT equipment, painted grey, inside the plant

Project Data

We manufactured a series of 16 shelters.

Client
Aventech
End user
Siemens Energy
Sector
Energy industry
Year
2026
Market where it was implemented
France
What was manufactured
10 m × 4 m × 4 m shelters
Services provided
Technical support for manufacturing, fabrication of the structure, painting and assembly of various elements
Certifications and standards
R30 intumescent protective paint and coating inspection by FROSIO Level 3 personnel
Project type
Series production based on the customer's design

From Drawing to Reality

The customer needed to turn its design of shelters for IT equipment into a manufacturable, fully equipped solution. The shelters had to include the metal structure, advanced fire protection, and the installation of sandwich panels, water gutters, closures and fireproof doors.

Welder working on the metal structure of a shelterMetal structures of several shelters lined up in the plant before assembly

Specific Coating Criteria

For our company, the main challenge was applying an intumescent coating for the first time on large-volume shelters, to meet an R30 fire-resistance requirement and reach thicknesses of up to 4,000 microns.

The difficulty lay not only in applying the coating, but also in correctly defining the process and resolving the technical details that arose during the work.

Strict Quality Control and Coordination

The solution was to define and validate the coating application process together with the paint supplier and the customer, through several technical visits and reviews of the procedure.

We also reinforced quality control with a FROSIO Level 3 inspector from our team, complemented by inspections by the supplier, the customer and a third party appointed by the customer. In this way, we ensured that the intumescent coating met the requirements established for the project.

Operator applying intumescent paint to the structure of a shelterShelter structure with the R30 intumescent coating already applied

Design, Manufacturing, Support and Verification

We started from the design provided by the customer, to which our team contributed technical support. We then fabricated and welded the shelters’ metal structures, before applying the coating.

The sandwich panels, water gutters, closures and fireproof doors were then installed, with the joint details and finishes also specified.

Strong, Safe Shelters

The project provided Aventech with a series of fully manufactured and equipped shelters to house IT equipment with enhanced fire safety.

In addition to the installation, we took charge of the detailed definition of the finishes and joints between the different elements, such as gutters, sandwich panels and other auxiliary components. This work requires a high level of precision to ensure watertightness, correct integration between systems and a consistent finish across the whole assembly. Attention to these small details directly improved the quality of the final result.

For the customer, this approach made it possible to centralise different phases of the project with a single supplier, from structural manufacturing to finishes and final assembly, which streamlined coordination and helped achieve the final result.

Key Metrics

Key project data.

  • 4,000 microns

    coating thickness

  • 16 shelters

    manufactured in two series of 8

  • FROSIO Level 3

    for coating inspection

Contact us
EPER Group certification seals: ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, UNE EN ISO 3834-2:2022, UNE EN 1090 EXC3 and EN15085-2 CL1

CONTACT